| |
|
|
| |
|
|
| |
|
| |
|
articles, posters and presentations |
| |
|
|
| |
|
| |
|
|
Bence Jones Proteinuria : experimentation
of a new immunoturbidimetric method
to determine Free Light Chains in non concentrated
urines |
| Biochimica
Clinica, 12, 1988, p.: 1451-1457 |
pdf: IT
|
| Abate L., Martelli M., Zannini R. |
| |
|
|
| original title: |
Proteinuria di Bence Jones:
sperimentazione di un nuovo metodo immunoturbidimetrico
per la determinazione delle Catene Leggere Libere
nelle urine non concentrate |
| comments: |
First article wich reports the study
of the functionality of the method for determining
FLCs by liquid-phase immunoprecipitation as a screening
test in the study of Bence Jones proteinuria. |
|
| |
|
| |
|
|
Immunoturbidimetric-Immunonephelometric
Method
for the determination of Free Light Chains in Urine |
| Meeting SIBioC/Proteine
– Asti 17-19 October1989 |
available
in (ref. BM-02) |
Massaro L.
New Scientific Company – Cormano (Milano) |
| |
|
|
| original title: |
Metodo Immunoturbidimetrico-Immunonefelometrico
per la Determinazione delle Catene Leggere Libere
nelle Urine |
| comments: |
Exhibition of the presentation of
the method at the congress on proteins held by the
SIBioC (Italian Society of Clinical Biochemistry)
in 1989. |
|
| |
|
| |
|
|
Use of the test-tube precipitation
test for urinary immunoglobulins
or their fragments present in monoclonal gammopathies |
| Biochimica Clinica,
13, 1989, p.: 1237-1240 |
pdf: IT
|
| Migliorati T. |
| |
|
|
| original title: |
Uso della prova di Precipitazione
in Provetta per Immunoglobuline Urinarie o loro frammenti
presenti in Gammopatie Monoclonali |
| comments: |
Another article which studies the
functionality of the method for determining FLCs
as screening in the study of Bence Jones proteinuria. |
|
| |
|
| |
|
|
| Letter to F. Aguzzi |
L’Angolo
dell’Elettroforesi - Biochimica Clinica, 14,
1990,
p.: 70-72 |
pdf: IT
|
Massaro L.
New Scientific Company – Cormano (Milano) |
| |
|
|
| original title: |
Lettera a F. Aguzzi |
| comments: |
Letter from L. Massaro to F. Aguzzi,
coordinator of the protein section in the magazine
of the SIBioC, in reply to his comments on the aforementioned
article by Abate L., Martelli M. and Zannini R. |
|
| |
|
| |
|
|
| AL Amyloidosis or AH Amyloidosis
? |
| Biochimica Clinica,
14, 1990, p.: 471-472 |
pdf: IT
|
| Alecci A., Brandini A. |
| |
|
|
| original title: |
Amiloidosi AL o Amiloidosi AH
? |
| comments: |
A case is reported in which the method
for determining FLCs by liquid-phase immunoprecipitation,
in this case in serum, is used to characterise the
type of amyloidosis from which the patient suffered. |
|
| |
|
| |
|
|
| Proposal of a working model
for research into Bence Jones Proteinuria |
| Poster - Proteins
ecc - Padova, 16-17 May 1991 |
available
in NSC (ref. BM-06) |
| Martelli M., Zannini R. |
| |
|
|
| original title: |
- |
| comments: |
Poster presented at the 1991 congress
of the SIBioC, showing the results obtained with
the use of the method for determining the FLCs,
automated in an APS nephelometer, as screening in
the study of BJPs. |
|
| |
|
| |
|
|
| Qualitative and Quantitative
Research of Bence Jones Proteins |
| Gior. It. Chim.
Clin., 16, 6, 1991, p.: 403-407 |
pdf: IT
|
| Valenti D., Lenzi MC., Mammmini P. |
| |
|
|
| original title: |
Ricerca qualitativa e quantitativa
delle Proteine di Bence Jones |
| comments: |
Another article in wich the application
of the method for determining FLCs in the study
of the BJPs is discussed. |
|
| |
|
| |
|
|
“Pseudo-oligoclonal”
Free Light Chains in urine:
Reflections resulting from recent works - Letter to
F. Aguzzi |
L’Angolo
dell’Elettroforesi - Biochimica Clinica, 16,
1992,
p.: 1213-1215 |
pdf: IT
|
Massaro L.
New Scientific Company – Cormano (Milano) |
| |
|
|
| original title: |
Catene Leggere Libere "pseudo-oligoclonali"
in urine: Riflessioni indotte da recenti lavori -
Lettera a F. Aguzzi |
| comments: |
Letter from L. Massaro to F. Aguzzi,
coordinator of the protein section in the magazine
of the SIBioC, which sets forth theoretical reflections
on a subject of wide discussion at the time, the
origin or cause of the electrophoretic pattern known
as ladders. |
|
| |
|
| |
|
|
| Utility of dosing Kappa and
Lambda Light Chains via Nephelometry |
| Poster –
XII Congreso SEQC - Murcia, 29-31 october 1993 |
available in NSC (ref. BM-09) |
Alsina M., Soler M., Vidal J., Pérez
E.
Laboratori Immunología – Hospital Mutua
de Terrassa – Terrassa (Barcelona) |
| |
|
|
| original title: |
Utilidad de la dosificación
de las Cadenas Ligeras Kappa y Lambda por Nefelometría |
| comments: |
Poster presented at the 1993 SEQC
congress (Spanish Society of Clinical Chemistry)
reporting the results obtained using the method
to determine FLCs as Screening in the study of BJPs. |
|
| |
|
| |
|
|
Assessment of Free Light Chain
nephelometric quantification
as Screening for Bence Jones Proteinuria |
| Poster –
XIII Congreso SEQC - Salamanca, 13-15 october 1994 |
available in NSC (ref. BM-10) |
Martinez-Bru C., Planella T., Cortés
M., González-Sastre F.
Laboratori Bioquímica – Hospital de la
Santa Creu i Sant Pau – Barcelona |
| |
|
|
| original title: |
Evaluación de la cuantificación
nefelométrica de Cadenas Ligeras Libres como
Screening de Proteinuria de Bence Jones |
| comments: |
Another Poster, presented at the
1994 SEQC congress, reporting the results obtained
using the method to determine FLCs as Screening
in the study of BJPs. |
|
| |
|
| |
|
|
Multicentric Evaluation of
Methods and Protocols for Free Light Chains
and Bence Jones Proteins in urine – First Results |
| Biochimica Clinica,
19, 1995, p.: 410-425 |
|
Milanesi MG. et altri
Commissione InterRegionale “Forlì”
su “Proteine di Bence Jones e Catene Leggere
Libere” |
| |
|
|
| original title: |
Valutazione Multicentrica di
Metodi e Protocolli per le Catene Leggere Libere e
Proteine di Bence Jones in urine - Primi Risultati |
| comments: |
This article reports the results
obtained by the “Forli” Study Group
in their first multicentric studies on methods and
protocols usually used to study Bence Jones proteinuria.
|
|
| |
|
| |
|
|
A new ImmunoNephelometric method
for Free Light Chains assay
in the Cerebrospinal Fluid of neurological patients:
preliminary results
European Charcot Foundation
Symposium “Body fluid markers for course and
activity of disease in Multiple Sclerosis” |
| Madrid, 2–4
october 1997 |
available in NSC (ref. BM-12) |
| Procaccianti G., Cucci A., Scaringi
R. Massaro L. |
| |
|
|
| original title: |
- |
| comments: |
Communication presented at the 1997
European Charcot Foundation congress, reporting
the results obtained using the method to determine
FLCs in cerebrospinal fluid in different neurological
affections, particularly in Multiple Sclerosis. |
|
| |
|
| |
|
|
Free Light Chains and Bence
Jones Proteins - Revision
I Edition: I Reunione su “Catene Leggere Libere
e Proteine di Bence Jones”, Forlì, 28
may 1993
II Edition: XIV Curs de Bioquímica Clínica,
Barcelona, 23-26 november 1994
III Edition: V Reunione su “Catene Leggere Libere
e Proteine di Bence Jones”, Forlì, 26
may 1995
IV Edition: Incontro “Proteine Urinarie - Clinica
e Diagnostica”, Pessaro, 23 june 1999
V Edition: Corso CEFAR “Le Proteine: dal Laboratorio
alla Clinica”, Desenzano, 13-15 october 1999 |
| V Edition, october
1999 |
pdf: ES
IT
|
Massaro L., Scaringi R.
New Scientific Company – Cormano (Milano) |
| |
|
|
| original title: |
Cattene Leggere Libere e Proteine
di Bence Jones - Review |
| comments: |
Complete revision of the argument
on the determination of Free Light Chains and Bence
Jones proteins, with special emphasis on their physiopathology,
theoretical aspects and problems of their determination
and revision of available methods.
It includes a large bibliographical list. |
|
| |
|
| |
|
|
Multicentric Evaluation of
Routine Commercial Methods
to detect Bence Jones Proteins in urine
Meeting SIBioC – CEFAR “Le Proteine:
dal Laboratorio alla Clinica” |
| VIII edition–
Desenzano, 1999 |
pdf: EN
ES
IT
|
Gruppi di studio “Forlì”
e “Liguria” su “Proteine di Bence
Jones e Catene Leggere Libere”
presentado por: Tizzanini W. (Laboratorio Analisi
– Azienda Policlinico – Modena) |
| |
|
|
| original title: |
Valutazione Multicentrica di
Metodi commerciali di routine per la ricerca delle
Proteine di Bence Jones nelle urine |
| comments: |
Presentation of results obtained
by the Study Groups “Forlì” and
“Liguria”, in their studies on methods
normally used in the study of BJP, at the joint
Meeting of the SIBioC and CEFAR Course on proteins.
Further information on the results obtained by the
Study Groups in their experiments can be found on
the page referring to BJP
Study Groups. |
|
| |
|
| |
|
|
Multicentric Evaluation of
routine commercial methods
to detect Bence Jones Proteins in urine
Meeting SIBioC – CEFAR “Le Proteine:
dal Laboratorio alla Clinica” |
| IX edition–
Fiuggi, 2000 |
pdf: ES
IT
|
Gruppi di studio “Forlì”
e “Liguria” su “Proteine di Bence
Jones e Catene Leggere Libere”
presentado por: Tizzanini W. (Laboratorio Analisi
– Azienda Policlinico – Modena) |
| |
|
|
| original title: |
Valutazione Multicentrica di
Metodi commerciali di routine per la ricerca delle
Proteine di Bence Jones nelle urine |
| comments: |
Presentation of the results obtained
by the Study Groups “Forlì” and
“Liguria”, in their studies on methods
normally used in the study of BJP, at the joint
Meeting of SIBioC and the CEFAR Course on proteins.
Further information, on results obtained by the
Study Groups in their experiments, can be found
on the page referring to BJP
Study Groups.
|
|
| |
|
| |
|
|
Evaluation and Presentation
of laboratory Results
in Patients suspected of a monoclonal Gammopathy:
The value of free light Chains in Bence Jones Testing
(Abstract)
Meeting SIBioC – CEFAR “Proteins:
from the Laboratory to the Clinic” |
| X edition –
Castrocaro, 2001 |
pdf: EN
ES
IT
|
Regeniter A.(a), Siede WH.(b)
(a) Presenting Author: Central Laboratory –
Kantonsspital Basel
(b) Author for correspondence: Central Laboratory
– Klinikum Lippe-Lembgo – Lembgo
E-mail:
Werner.Siede@klinikum-lippe.de |
| |
|
|
| original title: |
- |
| comments: |
Reports the study of the Free Kappa/Free
Lambda index functionality as a screening method
in the study of Bence Jones proteinuria, proposing
for patients suspected of monoclonal gammapathy,
the presentation of laboratory results in a single
computerized report including preliminary visit
data. |
|
| |
|
| |
|
|
Immunonephelometric Determination
of the Free Light Chains of Immunoglobulins in Urine
to Detect the Bence Jones Proteins and Comparison
with Immunofixation
Meeting SIBioC – CEFAR “Proteins:
from the Laboratory to the Clinic” |
| X edition –
Castrocaro, 2001 |
pdf: EN
ES
IT
|
Quinzanini M.
Servizio di Reumatologia Immunologia ed Allergologia
– Azienda Ospedaliera “Spedali Civili”
- Brescia |
| |
|
|
| original title: |
Determinazione ImmunoNefelometrica
delle catene leggere libere delle Immunoglobuline
nelle urine per la ricerca delle Proteine di Bence
Jones e confronto con l’Immunofissazione |
| comments: |
Reports the study of nephelometric
FLC determination functionality as a Screening method
in the study of Bence Jones proteinuria, making
an exhaustive comparison with Immunofixation taken
as a reference method.
It includes a complete study of the nephelometric
method performances and characteristics for FLC
determination.
|
|
| |
|
| |
|
|
Multicentric Evaluation of
Routine Commercial Methods to Detect
Bence Jones Proteins in Urine – Results 2001
Meeting SIBioC – CEFAR “Proteins:
from the Laboratory to the Clinic” |
| X edition –
Castrocaro, 2001 |
pdf: EN
ES
IT |
| Gruppi di studio su “Catene Leggere
Libere e Proteine di Bence Jones”: Forlì,
Liguria, Lazio, Toscana-Umbría presentado por:
Tizzanini W. (Laboratorio Analisi – Azienda
Policlinico – Modena) |
| |
|
|
| original title: |
Valutazione Multicentrica di
Metodi commerciali di routine per la ricerca delle
Proteine di Bence Jones in urine – Risultati
2001 |
| comments: |
Joint presentation of results obtained
by the different Italian Study Groups in their studies
on the methods usually used in the study of BJP.
Further information, on the results obtained by
the Study Groups in their experiments, can be found
on the page referring to the BJP
Study Groups.
|
|
| |
|
| |
|
|
Detection of Bence Jones Proteins
– A Contribution of the Genoese Galliera Hospital
Archives
Meeting SIBioC – CEFAR “Proteins:
from the Laboratory to the Clinic” |
| X edition –
Castrocaro, 2001 |
pdf: EN
ES
IT |
Burlando L.
Già Laboratorio Analisi – Ospedale Galliera
- Genova |
| |
|
|
| original title: |
Ricerca delle Proteine di Bence
Jones - Un contributo dall’archivio degli Ospedali
Galliera di Genova |
| comments: |
Via a retrospective study of the
hospital archives, the convenience/need to use anti
Free Light Chains antisera in urinary Immunofixation
is revised and discussed. |
|
| |
|
| |
|
|
Monoclonal and Polyclonal Immunoglobulin
Free Light Chains (FLC) detection in urine
Meeting SIBioC – CEFAR “Proteins:
from the Laboratory to the Clinic” |
| X edition –
Castrocaro, 2001 |
pdf: EN
ES
IT
|
Viedma JA.
Hospital General y Universitario – Elche (Alicante) |
| |
|
|
| original title: |
- |
| comments: |
Study of the capacity of different
methods to detect monoclonal and polyclonal FLCs
in urine. |
|
| |
|
| |
|
|
Proteinuria – Diagnostics
and Interpretation with Marker Proteins:
Computerising Processing and report (”MDI–LabLink”)
Meeting SIBioC – CEFAR “Proteins:
from the Laboratory to the Clinic” |
| X edition –
Castrocaro, 2001 |
pdf: EN
ES
IT
|
Siede WH.(a), Regeniter A.(b)
(a) Presenting Author: Central Laboratory –
Klinikum Lippe-Lembgo – Lembgo
(b) Author for correspondence: Central Laboratory
– Kantonsspital Basel E-mail:
aregeniter@uhbs.ch |
| |
|
|
| original title: |
- |
| comments: |
Explanation and revision of the concept
on the use of specific protein markers in the study
of proteinuria and presentation of the Software
“MDI-LabLink” enabling its computerization. |
|
| |
|
| |
|
|
| Usefulness of Determining Free
Light Chains in Urine via Nephelometry for the Study
of Bence Jones Proteinuria |
| Poster –
XXI Congreso SEQC - Gijón, 9-11 october 2002 |
pdf: ES |
Iglesias N., García-Vitoria M.,
Hernández M., Galimany R., Rodrigo MJ.
Laboratoris Clinics – Hospital Vall d’Hebrón
- Barcelona |
| |
|
|
| original title: |
Utilidad de la Determinación
de Cadenas Ligeras Libres en Orina por Nefelometría
para el Estudio de la Proteinuria de Bence Jones |
| comments: |
Study of the effectiveness of using
the FLC nephelometric measurement as Screening method
to detect Bence Jones proteinuria. |
|
| |
|
| |
|
|
Evaluation of an ImmunoFixation
Electrophoresis selective method for Bence Jones Proteinuria
Identification
15th European Congress of Clinical Chemistry and Laboratory
Medicine
22nd National Congress of the Spanish Society of Clinical
Biochemistry and Molecular Pathology (SEQC) |
| EUROMEDLAB –
Barcelona 2003 |
pdf: EN |
Quiñones-Torrelo C., Del Valle-Pérez
R., González-Ovelar M., Jarabo-Bueno MM., Díaz-Ruiz
M.,
Montagud-Palau A., González-Monleón
L., Marco-López P.
Sección de Inmunoquímica – Departamento
de Análisis Clínicos – Hospital
Universitari “Dr. Peset” - Valencia |
| |
|
|
| original title: |
- |
| comments: |
Study of the Immunofixation method
sensitivity used in the study of BJP in various
groups of patients classified according their FLC
concentration nephelometrically measured. |
|
| |
|
| |
|
|
ImmunoNephelometric Determination
of Free Light Chains in Urine as Screening for the
Detection of Bence Jones Proteinuria
15th European Congress of Clinical Chemistry and Laboratory
Medicine
22nd National Congress of the Spanish Society of Clinical
Biochemistry and Molecular Pathology (SEQC) |
| EUROMEDLAB –
Barcelona 2003 |
pdf: EN |
García-Vitoria M., Cortina A.,
Iglesias N., Hernández M., García-Guantes,
E., Besalú C., Galimany R., Rodrigo MJ.
Laboratoris Clinics – Hospital Vall d’Hebrón
- Barcelona |
| |
|
|
| original title: |
- |
| comments: |
Study of the effectiveness of using
the nephelometric measurement of FLC as a Screening
method to detect the Bence Jones proteinuria. |
|
| |
|
| |
|
|
ImmunoNephelometric Determination
of Free Light Chains of Immunoglobulins in Urine for
the Detection of Bence Jones Proteins, and Comparison
with Immunofixation
15th European Congress of Clinical Chemistry and Laboratory
Medicine
22nd National Congress of the Spanish Society of Clinical
Biochemistry and Molecular Pathology (SEQC) |
| EUROMEDLAB –
Barcelona 2003 |
pdf: EN |
Quinzanini M.
Servizio di Reumatologia Immunologia ed Allergologia
– Azienda Ospedaliera “Spedali Civili”
- Brescia |
| |
|
|
| original title: |
- |
| comments: |
Reports the study on the functionality
of the FLC nephelometric determination as a Screening
method in the study of Bence Jones proteinuria making
an exhaustive comparison with the Immunofixation
taken as the reference method.
To highlight the focus novelty, centered on improving
the quality of the process and final result obtained
(in the study of Bence Jones proteinuria) provided
by the use of nephelometry as a Screening method |
|
| |
|
| |
|
|
| Immunonephelometric Determination
of Immunoglobulin Free Light Chains in Urine |
| Analisis Clinicos
2003;28(1):7-14 |
pdf: ES Documento
|
Jiménez, M.; Preciado, E.; Mateo,
G.; Rodríguez, M. M.; García-Valdecasas,
I.
Laboratorio de Bioquímica - Hospital Txagorritxu
– Vitoria |
| |
|
|
| original title: |
Determinación Inmunonefelométrica
de Cadenas Ligeras Libres de Inmunoglobulinas en Orina |
| comments: |
Assessment of the Free Light Chain
measurement nephelometric method performances and
evaluation of its use as screening method in the
study of the Bence Jones proteinuria. |
|
| |
|
|
| |
|
|
| |
|
|
| |
|
other documents |
| |
|
|
| |
|
|
| |
|
| |
|
|
| Free Light Chains and Bence
Jones Proteins |
| Revision
– V Edition, October 1999 |
pdf: ES
IT
|
Massaro L., Scaringi R.
New Scientific Company – Cormano (Milano) |
| |
|
|
| original title: |
Cattene Leggere Libere e Proteine
di Bence Jones
Review – V Edizione, Ottobre 1999 |
| comments: |
Complete revision of the argument
on the determination of Free Light Chains and Bence
Jones proteins, with special emphasis on their physiopathology,
theoretical aspects and problems of their determination
and revision of available methods.
It includes a large bibliographical list. |
|
| |
|
|
| |
|
|
| |
|
| |
|
|
| Free Light
Chain Kits – Presentation |
pdf: EN
ES
IT
PT
|
Massaro L., Scaringi R.
New Scientific Company – Cormano (Milano) |
| |
|
| original title: |
Kit Cattene Leggere Libere -
Presentazione |
| comments: |
Presentation of the NSC´s Free
Light Chain kits. |
|
| |
|
|
| |
|
|
| |
|
| |
|
|
| Operative
Protocol for the BJP Study Proposal |
pdf: EN
ES
PT
|
S. Portas
New Scientific Company España – Barcelona |
| |
|
|
| original title: |
Propuesta de Protocolo Operativo
para el estudio de las BJP |
| comments: |
Proposal of operative protocol based
on the use of liquid-phase immunoprecipitation (nephelometry
or turbidimetry) as a first-level test, indicative
of the presence of free light chains (FLCs), followed
up by immunofixation as a confirmation test, to
determine whether or not the FLCs present are monoclonal,
i.e. Bence Jones (BJP). |
|
| |
|
| |
|
|
| Immunofixation (IFE) of urine
for Bence Jones Proteins detection, |
| Mini Atlas
of Schematic Pattern |
pdf: EN |
Massaro L.
New Scientific Company – Cormano (Milano) |
| |
|
|
| original title: |
- |
| comments: |
Revision of the typical urinary immunofixation
patterns found in the BJP study. |
|
| |
|
|